Deprecated: NewfoldLabs\WP\Module\Insights\Admin\Admin::__construct(): Implicitly marking parameter $repository as nullable is deprecated, the explicit nullable type must be used instead in /home4/nunafumy/public_html/wp-content/plugins/bluehost-wordpress-plugin/vendor/newfold-labs/wp-module-insights/includes/Admin/Admin.php on line 26

Deprecated: Mobile_Detect::__construct(): Implicitly marking parameter $headers as nullable is deprecated, the explicit nullable type must be used instead in /home4/nunafumy/public_html/wp-content/plugins/jet-menu/includes/lib/class-mobile-detect.php on line 684

Deprecated: Detection\MobileDetect::__construct(): Implicitly marking parameter $headers as nullable is deprecated, the explicit nullable type must be used instead in /home4/nunafumy/public_html/wp-content/plugins/jet-theme-core/includes/lib/class-mobile-detect.php on line 836

Deprecated: Detection\MobileDetect::setHttpHeaders(): Implicitly marking parameter $httpHeaders as nullable is deprecated, the explicit nullable type must be used instead in /home4/nunafumy/public_html/wp-content/plugins/jet-theme-core/includes/lib/class-mobile-detect.php on line 861

Deprecated: Detection\MobileDetect::setCfHeaders(): Implicitly marking parameter $cfHeaders as nullable is deprecated, the explicit nullable type must be used instead in /home4/nunafumy/public_html/wp-content/plugins/jet-theme-core/includes/lib/class-mobile-detect.php on line 949

Deprecated: Detection\MobileDetect::setUserAgent(): Implicitly marking parameter $userAgent as nullable is deprecated, the explicit nullable type must be used instead in /home4/nunafumy/public_html/wp-content/plugins/jet-theme-core/includes/lib/class-mobile-detect.php on line 999

Deprecated: Detection\MobileDetect::isTablet(): Implicitly marking parameter $userAgent as nullable is deprecated, the explicit nullable type must be used instead in /home4/nunafumy/public_html/wp-content/plugins/jet-theme-core/includes/lib/class-mobile-detect.php on line 1262

Deprecated: Detection\MobileDetect::isTablet(): Implicitly marking parameter $httpHeaders as nullable is deprecated, the explicit nullable type must be used instead in /home4/nunafumy/public_html/wp-content/plugins/jet-theme-core/includes/lib/class-mobile-detect.php on line 1262

Deprecated: Detection\MobileDetect::is(): Implicitly marking parameter $userAgent as nullable is deprecated, the explicit nullable type must be used instead in /home4/nunafumy/public_html/wp-content/plugins/jet-theme-core/includes/lib/class-mobile-detect.php on line 1293

Deprecated: Detection\MobileDetect::is(): Implicitly marking parameter $httpHeaders as nullable is deprecated, the explicit nullable type must be used instead in /home4/nunafumy/public_html/wp-content/plugins/jet-theme-core/includes/lib/class-mobile-detect.php on line 1293

Deprecated: Detection\MobileDetect::match(): Implicitly marking parameter $userAgent as nullable is deprecated, the explicit nullable type must be used instead in /home4/nunafumy/public_html/wp-content/plugins/jet-theme-core/includes/lib/class-mobile-detect.php on line 1322
Power Separators – NYWINT

Select a Component:

Power
Separator
System
Expansion
Power
Supply
Relay
Devices
Advanced
Components
Camera and
Telephone
Accessories

Power Separators

The Power Separator Supplies
24VAC Power to the 2-Wire System Bus

System Components – Click or Tap an Image:

Power
Separator
System
Expansion
Power
Supply
Relay
Devices
Advanced
Options
Camera and
Telephone
Accessories

Power Separators

The Power Separator module Supplies 24VDC to the 2-Wire Bus

DT-DPS (DR)
DT-DPS (V2)
PC7H
PC7
PC6A

DT-DPS (DR)  – Power Separator for 2-Wire Bus

DT-DPS (V2)  – Power Separator for 2-Wire Bus

Main Features:

  • Separates power for 2-wire bus components, Monitor Stations,
    modules and one Entry Panel
  • Use DR-60-24, PS5-24 or DR-30-24 power supply
  • DIN rail mounting – DT-DPS(DR) is also direct mounting
  • DT-DPS (V2) matches styling of Power Supply

PC7H  – 2.5 Amp Power Supply + DT-DPS (V2) Separator

PC7  – 1.5 Amp Power Supply + DT-DPS (V2) Separator

Main Features:

  • Combines the DT-DPS separator with a Power Supply in one set
  • PC7H includes the DR-60-24, 2.5 Amp Power Supply
  • PC7 includes the DR-30-24, 1.5 Amp Power Supply
  • DR-60-24 and DR-30-24 are UL listed
  • Universal AC input – 100 to 240 VAC, 50/60 Hz
  • 24 VDC output power (2.5 A or 1.5 A)
  • Power supply protection: short circuit, overload and over-voltage
  • DIN rail mounting

PC6A  – Power Supply and Separator

Main Features:

  • Combines the DT-DPS power separator functions
    with power supply in one unit
  • Universal AC input power: 100 – 240 VAC, 50/60 Hz
  • Power supply output: 24 VDC, 1.5 A
  • DIN rail mounting
  • Protection: Short circuit, overload  and over voltage
DT-DPS (DR)
DT-DPS (V2)
PC7H
PC6A
PC6A

DT-DPS (DR)  – Separator for 2-Wire Bus

DT-DPS (V2)  – Separator for 2-Wire Bus

Main Features:

  • Separates power for 2-wire bus components, Monitor Stations, modules and one Entry Panel
  • Use DR-60-24, PS5-24 or DR-30-24 power supply
  • DIN rail mount – DT-DPS(DR) also direct mount
  • DT-DPS (V2) matches style of Power Supply

PC7H  – 2.5 A Power + DT-DPS (V2)

PC7  – 1.5 A Power + DT-DPS (V2)

Main Features:

  • Combines the DT-DPS separator with
    Power Supply in one set
  • PC7H includes the DR-60-24, 2.5 A Power Supply
  • PC7 includes the DR-30-24, 1.5 A Power Supply
  • Both the DR-60-24 and DR-30-24 are UL listed
    with Universal AC input 100 to 240 VAC, 50/60 Hz
    and 24 VDC output power (2.5 A or 1.5 A)
  • Power supply protection: short circuit,
    overload and over-voltage
  • DIN rail mounting

PC6A  – Power Supply and Separator

Main Features:

  • Combines the DT-DPS power separator functions
    with power supply in one unit
  • Universal AC input power: 100 – 240 VAC,
    50/60 Hz; power supply output: 24 VDC, 1.5 A
  • DIN rail mounting
  • Protection: Short circuit, overload